ENGINEERED EXHAUST SYSTEMS · DATA CENTERS

SCR & acoustic silencers for data center backup generators.

One engineered solution for lower NOx emissions, controlled noise and reliable backup power. Designed and integrated by Filter Solutions S.L.

Integrated system designNew builds & retrofitEngineering for international projects

What emission system does a data center backup generator need?

There is no single configuration. The system is defined from the NOx target, exhaust temperature and flow, maximum allowable backpressure, real duty cycle, acoustic target and available installation space.

Depending on those inputs, the solution may combine an acoustic silencer, SCR with AdBlue/DEF and, where required and technically viable, a DOC or DPF. The aim is to reduce emissions and noise without exceeding the engine's operating limits.

One system. Engineered around your generator.

We manufacture and integrate complete exhaust solutions rather than supplying a standalone catalyst. The core solution combines acoustic attenuation and selective catalytic reduction (SCR), with further treatment when required.

PRIMARY SOLUTION

Acoustic silencer + SCR

Integrated or modular exhaust assemblies combining NOx reduction, sound attenuation, AdBlue/DEF dosing, mixing, control and service access.

SCRACOUSTICSCONTROLS
OPTIONAL MODULE

Diesel oxidation catalyst (DOC)

An additional stage to address CO and hydrocarbons (HC), subject to engine data, operating conditions and emissions targets.

COHC
OPTIONAL MODULE

Diesel particulate filter (DPF)

Particulate control where required, with regeneration strategy and operating temperatures assessed during feasibility engineering.

PMREGENERATION

Designed for the real constraints of standby power.

Backup generators do not behave like continuously operating engines. The system must respect the actual duty cycle without compromising engine operation.

01

Real operating temperatures

Start-up, short test runs and low-load operation determine SCR activation and performance.

02

Maximum allowable backpressure

We check exhaust flow and pressure loss against the engine manufacturer’s limits.

03

Acoustic requirements

Silencer geometry and attenuation targets are engineered alongside the emissions stages.

04

Space, access & controls

Layouts for enclosures, plant rooms or external skids, with dosing, sensors and serviceability in mind.

The data required to size an SCR and acoustic system correctly.

The more complete the real generator data, the more accurately the catalyst, dosing system, silencer and backpressure can be assessed.

InputWhy it matters
Engine make, model and powerEstablishes the calculation basis, operating range and OEM limits.
Exhaust gas flowDefines cross-section, gas velocity and system sizing.
Temperature profileDetermines SCR activation and AdBlue/DEF dosing strategy.
Engine-out NOx and targetSupports catalyst volume and reduction strategy sizing.
O₂ and H₂O, when availableImproves exhaust-gas characterisation for catalyst calculations and selection.
Maximum allowable backpressureAllows the complete system to be checked against engine limits.
Acoustic targetDefines required attenuation and silencer design.
Operating hours, starts and loadDescribes the real testing, standby and partial-load duty cycle.
Available space and layoutDefines architecture, maintenance access and stack arrangement.

A single technical partner from study to commissioning.

01

Assess

Engine data, exhaust conditions, emission and acoustic objectives, space and local permit needs.

02

Engineer

Sizing, pressure-loss checks, mixing, catalyst selection, exhaust and acoustic integration.

03

Manufacture & integrate

Fabrication and supply of the engineered exhaust assembly, dosing and control components.

04

Commission & support

Installation coordination, calibration, validation and optional monitoring or maintenance support.

Emission targets depend on the installation — not just the engine.

EU Directive 2015/2193 and national regulations may apply to eligible combustion installations. Local permits, operating hours and project-specific conditions must also be assessed. An SCR is not automatically mandatory for every emergency generator.

EU Medium Combustion Plant Directive Technical and regulatory scope are confirmed during project assessment. No blanket compliance claim is made.

The questions engineers ask first.

Is SCR compulsory for every data center standby generator?

No. Applicability depends on rated thermal input, operating hours, national implementation and the conditions of the site permit. We review the target emissions requirements before selecting a technical solution.

Can SCR and the exhaust silencer be supplied as one system?

Yes. We engineer combined or modular configurations based on allowable backpressure, acoustic targets, exhaust temperature, flow and available space.

Can a DOC or DPF be added?

Yes, where required and technically viable. DOC targets CO/HC; DPF addresses particulate matter. Each addition changes the design and pressure-loss budget, and DPF suitability depends on regeneration conditions.

What information is needed to start?

Engine make and model, rated power, exhaust flow and temperature, maximum backpressure, generator duty cycle, acoustic requirement, NOx target, site country and available installation space.

Planning a data center generator project?

We assess noise attenuation and NOx treatment together. Share engine specifications, emissions targets and acoustic requirements for an initial feasibility review.

TECHNICAL ASSESSMENT

Useful project data for an initial review

  • Engine manufacturer, model and power rating
  • Generator quantity and installation location
  • Exhaust flow, temperatures and allowable backpressure
  • NOx and noise requirements; available footprint
  • Operating hours, starts and project timeline
Open Filter Solutions contact form Open technical contact form